Thermal engineering calculator for enclosing structures

Conditional one-dimensional calculation of a multilayer structure: GSOP, heat transfer resistance, temperature profile, selection of insulation thickness and transmission heat losses of the building.

Construction area

Building and climate

Source of set: SP 131.13330.2025.

Group influences choicepolicy and type of building; numerical norms are taken from published sets.

m²

Room

Calculated air parameters
°C

Determined by the purpose of the room.

Interface validation range: 5…110 °C.Interface validation range: 5…110 °C.

°C

Interface validation range: 5…110 °C.Interface validation range: 5…110 °C.

%

%

An explicit reference value for estimating partial pressure.

Accepted according to Appendix A SP 50.13330.2024.

Temperature and humidity are user-entered calculation values.

Humidity conditions—
terms of Use—

Fencing

Type and outdoor environment

Preset thicknesses — engineering UI values; selection does not establish code compliance.Preset thicknesses are engineering UI values; selection does not establish code compliance.

Framed wall and sandwich-panel presets are omitted: the published catalog lacks the complete material and component properties needed for a reliable assembly model.Framed walls and sandwich panels are omitted because the published catalog does not contain the complete material and component data for a reliable assembly model.

Layers

Inside → outside

ThermalCalc

Directory of materials

MaterialCategoryρλAλBVapor permeabilitySource

Select a line to see available characteristics.

What does the calculator calculate?

The “Design” mode calculates the conditional resistance to heat transfer, coefficientU, stationary heat flow, temperatures at the boundaries of layers and conditional seasonal transmission loss after 1 m². The "Building" mode collects structures, rooms and surfaces, then displays transmission losses for each room and building in W and kW.

What's happenedR conditional andR given

ConditionalR describes a homogeneous one-dimensional area. GivenR takes into account racks, fasteners, joints, corners and other heat-conducting inclusions. This calculator does not determine the reduced resistance and does not confirm full compliance with the joint venture design.

How is GSOP calculated?

GSOP= (tᵢ − tₕ) × zₕ

The internal temperature for GSOP is set separately from the temperature of the current calculation. For Samara, the average temperature and duration of the heating period are taken from SP 131.13330.2025; for category 1.2, a period with an average daily temperature not exceeding 10 is used°C, for categories 1.1 and 2 - no higher than 8°C.

How to chooseλA /λB

The humidity regime of the room is determined by temperature and relative humidity, then, together with the selected humidity zone, it sets operating conditions A or B. From the userλA andλB the value of the corresponding mode is selected.

How is layer resistance calculated?

Rᵢ = δ / λ × γ

Thicknessδ Converted from millimeters to meters. Coefficientγ default is 1.00; any other value is explicit user input.

How to choose the thickness of insulation

The resistances of surfaces and other layers are subtracted from the basic normalized value. The missing resistance of the marked layer is converted into thickness according to its calculated thermal conductivity andγ. Rounding up to 10 mm is only a design recommendation.

Calculation Limitations

Heat-conducting inclusions, frames, ground floors, vapor permeability, condensation, moisture accumulation, ventilation, infiltration and the full heat balance of the building are not calculated. For windows and doors in building modeU set by the user or according to the manufacturer. The temperature difference of a homogeneous area is given for reference and is not a complete sanitary and hygienic check. Temperatures in corners and joints may be lower than the result for a homogeneous area.

Regulatory framework

  • SP 50.13330.2024 “Thermal protection of buildings”;
  • SP 131.13330.2025 “Building climatology”.

SP 345.1325800.2017, GOST R 54851-2011, GOST R 59985-2022 and GOST 30494-2011 are provided for future expansion, but additional functions for them are inv0.1 not implemented.