How to use the calculator
Specify outer diameterD and wall thicknesst in millimeters, then the length of one element in meters and the whole number of pipes. Fractional values can be entered separated by a period or a comma.
Calculation formula
S = π / 4 × [D² − (D − 2t)²]
m₁ = S × 10⁻⁶ × ρ
The square difference describes the area of the ring between the outer and inner diameters. SquareS turns out in mm² and converted to m². Density of steelρ taken equal to 7850 kg/m³; m₁ expressed in kg/m.
Designations
- D
- outer diameter of the pipe, mm;
- t
- wall thickness, mm;
- D−2t
- internal diameter of the pipe, mm;
- S
- metal section area, mm²;
- ρ
- steel density, 7850 kg/m³;
- m₁
- estimated weight of one linear meter, kg/m.
Calculation example
For pipeD = 57 mm andt = 3 mm internal diameter is 51 mm, cross-sectional area is 508.94 mm², and the mass of one meter is 3.995 kg. A 6 m long pipe has a calculated mass of 23.97 kg.
Accuracy and Limitations
The result is the geometric design mass of the idealized annular section. The calculation does not take into account dimensional tolerances, production features and the actual density of the material. This is not a normative value of the assortment and not a statement of compliance with a specific GOST.